How to troubleshoot Furnace American Standard auh1b060a9361aa - blower not running

Furnace - one of the most wanted appliances at home. It’s difficult to imagine your life without Furnace, and when it stops working or gives some trouble, like blowers not running - better to fix it asap. In this case better solution - replace furnace circulation blower motor. We have instructions on how to replace it on furnace American Standard auh1b060a9361aa. 

The blower fan motor is normally supported on rails near the bottom of the furnace. Since the motor power wires are connected to a control board that is often located in an upper compartment, two access panels may need to be removed. If applicable, you should ensure the motors run capacitor is discharged by placing a screwdriver with an insulated handle across the terminals. Avoid touching the screwdriver blade. Disconnect the wires from the capacitor terminals, if required. Depending on the furnace model, you may have to uninstall a drain trap assembly, and the attached hoses to access the fan motor. If necessary, you may need to disconnect the thermostat wires from the control board to move them out of the way. Note the orientation of the blower motor power wires, then disconnect them from the control board. Cut any zip ties if required. Move any additional obstructions out of the way. If necessary, note where the blower assembly mounting rails are positioned. Now unthread the screws securing the rails. Carefully slide out the blower assembly. Use an adjustable wrench to loosen the set screw to release the blower wheel from the motor shaft. If required detach the grounding wire. Cut any zip ties securing the motor wires. Now unthread the bolts or screws securing the blower motor. Note the orientation of the old motor, then lift it off of the blower housing. When installing a new blower motor, you should confirm that the motors capacitor rating matches the existing run capacitor. If not, you will need to replace the capacitor with the required one. Insert the fan motor shaft into the blower wheel, as you properly align the motor on the housing. Thread and tighten the bolts or screws to secure the motor. Use zip ties to secure the wires and reattach the grounding wire if required. With the flat side of the motor shaft facing the set screw, center the blower wheel in the housing and tighten the set screw. Realign the blower assembly mounting rails with the slots on the support, and slide the assembly into position. Replace the screws to secure the rails. Reinstall any components you removed earlier. Attach the blower motor power wires to the appropriate terminals on the control board. Connect the capacitor wires, as required. If applicable, reconnect the thermostat wires as well. Use zip ties to remove any slack from the wiring. With the new blower motor installed, replace the access panel or panels. Turn the power supply back on, and your furnace should be ready for use.

We hope that our guide will help you to fix troubles with the furnace. Feel difficulties during the process? You can contact our customer support team and arrange an appointment at the convenient time.


November 26, 2023

AC is leaking from the coil – HVAC Troubleshooting in San Diego

Have you encountered a leaking air conditioner? This causes not the most pleasant feelings and deprives you of comfort. Before solving this problem, you should determine what exactly became the source of the air conditioner flow.
HVAC Repair
November 26, 2023

Cracked Evaporator Coil – AC Repair in San Marcos

The need to carry out complex diagnostics of the air conditioner most often arises when the unit does not turn on, or there is some irregularity in the operation of the air conditioning equipment.
HVAC Repair
November 26, 2023

Carrier AC Fan Won’t Work – HVAC Maintenance in Carlsbad

A comfortable temperature is a critical component that influences pleasant work in an office space and relaxation in the room. A malfunction in the air conditioner becomes a real problem for the system owner. One of the most popular malfunctions is a lifeless external air conditioner unit fan.
HVAC Repair
November 26, 2023

No air coming out of the vent – AC Repair in San Diego

One of the most common problems homeowners face is the supply of warm air from the air conditioner. This problem can catch you by surprise and cause not the most pleasant feelings, especially if it happens on a sweltering day.
HVAC Repair
November 26, 2023

AC Control Panel is Blank – HVAC Inspection in San Diego

It is often the case that a certain breakdown detected in the device can have several causes of origin. At the same time, the root cause of the malfunction does not always lie in the element in which it first appears.
HVAC Repair
November 22, 2023

AC Diagnostics in San Diego

The purpose of servicing air conditioners is to maintain the technical characteristics of the air conditioner in a given range of values, as well as to eliminate malfunctions that occur during equipment operation.
HVAC Repair
November 22, 2023

Carrier A/C Isn’t Working – HVAC Diagnostics in Folsom

Several symptoms alert about an air conditioner breakdown. No cooling, frequent cycling on and off, noises, hot or warm air blowing are among them. If you suspect your Carrier A/C in functioning incorrectly, it will be reasonable to arrange a maintenance visit.
HVAC Repair
November 22, 2023

Goodman AC isn’t working – AC System Repair in Escondido

The owner of this Goodman AC system has complained about a refrigerant leak. The refrigerant pressure on the working system is below 30 Psig when it should be 60 Psig for the proper cooling effect. Refrigerant refill may solve the issue only temporarily. A Prime Air Solutions expert can offer either to find the leak and fix it or to replace the broken component.
HVAC Repair
November 22, 2023

AC Maintenance job in La Mesa

Timely maintenance of air conditioners guarantees the equipment’s long and high-quality functioning and its long life. It also saves on maintenance, and most importantly, it ensures the health and well-being of everyone using the equipment.
HVAC Repair
November 22, 2023

Carrier AC is noisy and not blowing – HVAC Tune-up in San Diego

Air conditioners have a moderate noise level; the usual buzzing is a variant of the norm. But a sharp increase in the sound level, as well as the appearance of unusual noises, on the contrary, should alert the owner. This is a sign of the need to diagnose the air conditioner immediately.
HVAC Repair
November 22, 2023

Carrier HVAC system is not turning off – AC Repair in San Diego

Oops! Your HVAC system is not turning off after using heat for the first time since last year. No panic! Prime Air Solutions technicians reveal that it's rather common for heating systems. It could be as simple as a broken thermostat or an electrical problem.
HVAC Repair
November 22, 2023

A/C Inspection in Ramona

Air conditioning systems are designed to improve the climatic conditions in residential and public spaces, and they do a good job of it. However, over time, the efficiency of climate technology decreases. This happens due to dust settling on radiators and filters, a drop in refrigerant pressure, wear of parts, or other reasons.
HVAC Repair
November 19, 2023

Furnace isn’t working – HVAC Maintenance in Sacramento

When your furnace doesn’t come on, it can be due to complicated or very simple reasons. If thermocouples, wiring, heat exchangers, or blower motors' performance is in doubt, it's better to contact a qualified professional. Professional check-up quickly shows the real reason for the trouble.
Furnace
November 19, 2023

Midea A/C is leaking – HVAC Diagnostics in Ramona

Water from the air conditioner can drip from both indoor and outdoor units. When the air conditioner operates in cooling mode, condensation forms on the internal heat exchanger, flows into the drainage bath, and goes through the drainage pipe to the street or the sewer. If the drain channel is clogged, the drainage basin fills up, and water leaks onto the walls.
HVAC Repair
November 19, 2023

AC Won’t Heat – AC Maintenance in Carmichael

If your heater turns on but refuses to heat the air, it is better to have a check-up. A dirty or clogged inducer motor may result in reduced airflow. This can lead to inadequate venting of combustion gases, potentially causing safety concerns. Additionally, reduced airflow might impact the overall efficiency of the heating system.
HVAC Repair